[vc_empty_space][vc_empty_space]
Lightning characteristics and performance of distribution system around Jakarta
Hidayat S.a, Haryanto N.a, Sriyatmo E.b
a Bandung Institute of Technology, Indonesia
b PT PLN (Indonesia Power Company), Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]A real-time lightning location network started to operate in Indonesia in mid 1995 and began providing reliable data in the end of the same year. The network consists of 8 signal receiving stations and works using the Time-Of-Arrival (TOA) technique. The present paper reports on lightning characteristics observed by the LPATS-III network for 5 consecutive years from 1996 to 2000 on the Java Island, Indonesia. Performance of MV distribution system in Jakarta recorded for the same period is analyzed in the relation with the lightning activity. Lightning activity on the Island shows a consistent high density. The spatial and temporal distribution of lightning activity on the Island as reported by Hidayat and Ishii are confirmed. OH lines outages and temporary outages dominate the performance of MV distribution line in Jakarta. Both types of outages show exhibit strong correlation with lightning activity. The performances of OH lines and cable for Jakarta distribution system are estimated 36.2 and 24.6 outages per 100 km per year, respectively.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Lightning detection networks[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Distribution lines,Jakarta,Lightning activity,Lightning characteristics,Lightning detection network,Outages,Temporary outages[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]