Enter your keyword

2-s2.0-2942635835

[vc_empty_space][vc_empty_space]

Combined air conditioning and tap water heating plant using CO2 as refrigerant

Adriansyah W.a

a Thermodynamic Research Laboratory, Inter University Research Center, Institut Teknologi Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]A combined air conditioning and tap water heating plant using carbon dioxide (CO2) as refrigerant has been investigated theoretically and experimentally. The system is suitable for countries with year around cooling demand, such as Indonesia or Singapore, and a need for hot tap water. A unique CO2 transcritical cycle characteristic for heating process can afford an improvement to a CO2 air conditioning system when rejected heat from the system is recovered. Some parameters affecting performance of the combined system are discussed. © 2004 Elsevier B.V. All rights reserved.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Combined ac and water heating,Optimum pressure,Transcritical cycle,Water heating[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Carbon dioxide,Combined ac and water heating,Optimum pressure,Transcritical cycle[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text]This paper is part of doctoral work carried out at Department of Refrigeration and Air Conditioning, Norwegian University of Science and Technology (NTNU). The study was funded for the first semester by Direktorat Jenderal Pendidikan Tinggi Indonesia and the rest by Ministry of Education, Research, and Church Affairs (KUF) in cooperation with International Office of NTNU and The Norwegian Educational Loan Fund, through Quota Program. Their supports have been highly appreciated.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1016/j.enbuild.2004.01.014[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]