Enter your keyword

2-s2.0-78049408578

[vc_empty_space][vc_empty_space]

Concurrent calorimetric and interferometric studies of steady-state natural convection from miniaturized horizontal single plate-fin systems and plate-fin arrays

Harahap F.a, Lesmana H.b, Sambegoro P.L.c

a Thermal Engineering Laboratory, Faculty of Mechanical and Aerospace Engineering, Institute of Technology of Bandung (ITB), Indonesia
b GroundProbe Pty Ltd, Australia
c Mechanical Engineering Department, MIT, United States

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]Concurrent calorimetric and interferometric studies have been conducted to investigate the effect that reduction of the base-plate dimensions has on the steady-state performance of the rate of natural convection heat transfer from miniaturized horizontal single plate-fin systems and plate-fin arrays. The effect was studied through comparison of the present results with those of earlier relevant calorimetric, interferometric, or numerical studies. Results shown that a reduction of the base-plate area by 74% increased natural convection coefficient by 1.5 times to 26.0 W m-2K-1 for single fin systems and by 1.8 times to 18 W m-2K-1 for fin arrays in the range of the base-plate temperature excess of 20-50°C. A simple correlation for the Nusselt number of miniaturized horizontal plate-fin arrays is proposed in the range of Rayleigh number divided by the number of fins to the 2.7 power from 2 × 10 to 5 × 105. © 2010 Springer-Verlag.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Convection coefficients,Fin arrays,Horizontal plates,Natural convection heat transfer,Numerical studies,Plate fins,Plate temperature,Rayleigh number,Single plates,Steady state performance,Steady-state natural convection[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1007/s00231-010-0626-2[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]