Verification of harmonic effects on electrical energy measurements accuracy (AMR based) in PT. PLN Distribution West Java and Banten

Mawardi A.a, Purwadi A.b, Pranyotoa, Firmansyah M.a, Heryana N.b, Nurafiat D.b

a PT. PLN Research and Development, Indonesia
b School of Electrical Engineering and Informatics, Institute of Technology Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]Automated meter reading system usually provided only for big customer energy metering. This paper discusses the verification of energy measurements under harmonics condition for three big customers connected to 150/70 kV high voltage and 20 kV medium voltage distribution networks of PT. PLN Distribution (a state owned electric utility company) West Java & Banten area. Harmonic effects differ substantially depending on the characteristics of the affected devices, such as metering device. The electronic energy metering system generally provided with better capability for measuring a non sinusoidal distorted current compare to previous electromechanical energy metering system due to true rms feature measurement capability. However certain periodic verification still needed to check the accuracy of AMR system installed, especially under certain harmonic load condition exposed. The verification was done by comparing the measurement results from AMR system using EDMI MK6E with the measurement results from Power Quality Meter Topaz 1000, under synchronize time for certain duration during high load and low load conditions. The comparative measurement results show that energy measured by AMR system for the three big customers are still in their accuracy class range. © 2011 IEEE.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]amr system,energy metering,Harmonic effects,Total harmonic distortions,true rms[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]amr system,energy metering,harmonic effects,power quality,total harmonic distortion,true rms[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICEEI.2011.6021691[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]