The determination of critical points on High Voltage/Extra High Voltage over-head lines caused by lightning strikes using Severity Indexes method

Yudo Pramono E.a, Hakam D.F.a, Zoro R.b

a Transmission and Load Dispatch Centre of Sumatra, PLN P3B Sumatera, Planning Department, Indonesia
b Power Engineering Division, School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]High Voltage / Extra High Voltage over-head lines performance to the lightning strikes can be determined by using lightning strike to ground density level. Thus, an evaluation of the High Voltage / Extra High Voltage over-head lines performance calculation can be accurately done using the density of lightning strike to ground on regions that are passed through the transmission lines. Based on the calculation when it is found above the standard design of the transmission lines, there will be improvements to increase the performance itself. Lightning strikes density data found by the lightning strikes detection system will provide two data, which are: lightning strikes to ground density level and striking points. When both data are combined with coordinate location data of a high voltage / extra high voltage over-head lines using Global Positioning System (GPS), it will be known the unsafe level of lightning strikes in the transmission lines. A Severity Indexes method will count the unsafe level of high voltage / extra high voltage over-head lines with consideration of tower parameter, geographic tower location and density level of lightning strikes to ground. This method is useful for determining all unsafe points along the transmission lines which will be compared with the data of broken insulators in transmission lines. Thus, it can be optimised in the determination of repaired towers by economical consideration and reparation reliability at the exact tower of reducing failures and increasing performance. © 2011 IEEE.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Back flashover,Critical points,Density data,Density levels,Detection system,Extra high voltage,High voltage,Lightning strikes,Location data,Performance calculation,Protection failure,Severity Indexes,Standard design,Striking point[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Back flashover,Lightning Strike Density,Protection Failure,Severity Indexes[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICEEI.2011.6021511[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]