Enter your keyword

2-s2.0-80054049171

[vc_empty_space][vc_empty_space]

State-of-the-art of lightning protection system of high-rise building in Jakarta

Darwanto D.a, Hamdani D.a

a Power Engineering Division, School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]Situated along equatorial-line region Indonesia is exposed to lightning with relative high isokeraunic level. Hence, high reliable lightning system becomes compulsory for high-rise buildings, which are subject to lightning strike with relative high probability. However, in fact, this is not the case when we realize the quality of lightning protection system installed within most of high-rise building at a glance observation. This paper presents state-of-the-art of the existing lightning protection system installed within high-rise buildings in Jakarta considered as the representative case of Indonesia. Some technical aspects of the surveyed systems are discussed from EMC point of view. Furthermore, an example design of EMC-based lightning protection system is described. Our survey results realize that high-rise buildings are mostly not well equipped with the proper lightning protection system. Furthermore, about 80% of high-rise buildings installed lightning protection system based on non-conventional concept, which is scientifically and legally not recognized. This adverse condition exists due to lack of knowledge of the society and weak law enforcement of the authorities. © 2011 IEEE.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]High probability,High reliable,High rise building,Indonesia,Jakarta,Lightning protection systems,Lightning strikes,Lightning systems,Representative case,Technical aspects[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]electromagnetic compatibility,lightning protection[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICEEI.2011.6021685[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]