Enter your keyword

2-s2.0-81855176180

[vc_empty_space][vc_empty_space]

Thermodynamics study of flash-binary cycle in geothermal power plant

Pasek A.D.a, Fauzi Soelaiman T.A.a, Gunawan C.a

a Thermodynamics Laboratory, Institute Technology Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]This paper was conducted to evaluate the performance of a flash-binary cycle if applied to geothermal power plant (PLTP), where the source of heat came from the residual brine from the separator which was generally re-injected into wells. In the study of flash-binary cycle, there are four types of organic working fluids considered for the binary cycle, namely i-pentane, n-pentane, i-butane, and n-butane. Optimization process was carried out on the performance of plant systems. This paper also discussed the limitation factor to get maximum net power, like: flash pressure, evaporator pressure, Δ pinch temperature, scaling formation, and thermal design in heat exchanger (preheater, evaporator, and air cooled condenser). © 2011 Published by Elsevier Ltd. All rights reserved.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Air-cooled condensers,Binary cycles,Evaporator pressure,Limitation factors,Organic working fluid,Residual brines,Scaling formation,Thermal designs[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Flash-binary cycle,Heat exchanger,Optimization,Organic working fluid[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1016/j.rser.2011.05.019[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]