Enter your keyword

2-s2.0-84857208552

[vc_empty_space][vc_empty_space]

Summation convolution filtered back projection and algebraic reconstruction technique for ring array ultrasound tomography based on time of flight

Ain K.a,b, Kurniadi D.a, Trisnobudi A.a, Santoso O.a

a Engineering Physics Program, Institut Teknologi Bandung, Indonesia
b Physics Departement, Airlangga University, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]Purpose of the study is to apply SCFBP and ART methods on a ring array ultrasound tomography system based on time of flight. The study was conducted with numerical and experimental object by 16 positions in circular phantom. The data set of ring array was rearranged and interpolated into parallel scheme to reconstructed by SCFBP and ART methods. The result indicated that rearrangement and interpolation is feasible to use SCFBP methods, improve speed and reconstructed image quality on ART methods. © 2011 IEEE.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]ART methods,Ring arrays,SCFBP method,Time of flight,ultrasound tomography[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]ART methods,ring array,SCFBP method,time of flight,ultrasound tomography[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICA.2011.6130170[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]