Enter your keyword

2-s2.0-84859072102

[vc_empty_space][vc_empty_space]

Implementation of Gabor filter to texture analysis of radiographs in the assessment of osteoporosis

Mengko T.R.a, Tjandra Pramudito J.a,b

a Department of Electrical Engineering, Institut Teknologi Bandung, Bandung, 40132, Indonesia
b Universitas Katolik Parahyangan, Bandung, 40141, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2002 IEEE.Multi-channel filtering implemented using the Gabor function, or Gabor filter, is capable of mimicking characteristics of the human visual system. In the assessment of osteoporosis, Gabor filter is used to calculate features from a trabecular pattern recorded on radiographs of a proximal femur. The assessment of osteoporosis can be done by observing and analyzing the trabecular pattern in the proximal femur. The feature extraction method used is energy calculation. The energy then is used for assessment or classification. The predetermined Singh index of the trabecular pattern is used to justify the classification result.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Frequency,Humans,Image texture analysis,Osteoporosis,Pattern analysis,Visual systems[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Diagnostic radiography,Feature extraction,Filtering,Frequency,Gabor filters,Humans,Image texture analysis,Osteoporosis,Pattern analysis,Visual system[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/APCCAS.2002.1115217[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]