Enter your keyword

2-s2.0-84862899939

[vc_empty_space][vc_empty_space]

Carbon paste electrode modified with carbon nanotubes and poly(3-aminophenol) for voltammetric determination of paracetamol

Noviandri I.a, Rakhmana R.a

a Analytical Chemistry Research Group, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]In this research, carbon paste electrode (CPE) was modified with carbon nanotube (CNT) and poly(3-aminophenol) and the modified electrode was used for voltammetric determination of paracetamol. The CNT used to modify CPE was synthesized using spray pyrolysis technique and characterized using Scanning Electron Microscopy (SEM), Transmission Electron Microscopy (TEM), and Energy Dispersive X-Ray (EDX) techniques. Modification of CPE was conducted firstly by dispersing CNT on the surface of CPE from its N, N-Dimethil fomamide (DMF) suspension and then CNT was trapped in poly(3-aminophenol) through electropolymerization of 3-aminophenol on the surface of CPE. Characterization of the modified electrode was conducted with squarewave voltammetry (SWV) technique. Oxidation peak of paracetamol was 450 mV vs Ag/AgCl(3 M NaCl). Oxidation current of paracetamol obtained with the modified CPE was significantly higher than that obtained with bare CPE. The best calibration curve for paracetamol was in the concentration range of 10 -5 M – 10 -4 M with limit of detection (3σ) of 1,1 μM. Results of paracetamol determination in real sample with the modified electrode were in good agreement with those of HPLC method. © 2012 by ESG.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]3-aminophenol,Carbon nanotube,Carbon paste,Paracetamol,Voltammetry[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]