[vc_empty_space][vc_empty_space]
Fix series capacitor for increasing power transfer on transmission 150 kV at Sumatera interconection system
Nurdin M.a, Hariyanto N.a, Sasmono S.a, Rahmani R.a, Armainib, Faizal R.c
a School of Electrical Engineering and Informatics, Bandung Institute of Technology, Indonesia
b Centre of Research and Development/Puslitbang, PT PLN (Persero), Indonesia
c PT PLN (Persero) P3BS, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]The power transfer restrictions on the transmission lines 150 kV in Sumatera Interconnection System caused electric power generated by the power plant with lower cost in fuel at Southern Sumatera cannot be optimally delivered to the load centers in Northern Sumatra. One of technical solution that is expected to solve this problem is fixed series capacitor installation in tie line Lubuk Linggau-Bangko. It is connecting Southern Sumatera and Northern Sumatera through Central Sumatera. Simulation carried out with Digsilent 12.0. Simulation results indicate a maximum transfer can be improved, however system stability is become lower but still at safe limits. © 2012 IEEE.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Electric power,Interconnection systems,Load centers,Maximum power transfer,Power transfers,Series capacitors,Sumatra,Technical solutions,Tie line[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]fix series capacitor,maximum power transfer,tie line,transmission 150 kV[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/CMD.2012.6416206[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]