Enter your keyword

2-s2.0-84884964052

[vc_empty_space][vc_empty_space]

Response function of collimated detector for non axial detector-source geometry

Wirawan R.a,c, Djamal M.a, Waris A.a, Handayani G.a, Kim H.J.a,b

a Department of Physics, Bandung Institute of Technology, Indonesia
b Radiation Science Research Institute, Department of Physics, Kyungpook National University, South Korea
c Department of Physics, FMIPA Mataram University, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]Response function is a fundamental parameter for all detectors in order to analyze the energy distribution of gamma ray which undergoes scattering interaction with the material. The response functions of a 3 in. x 3 in. NaI(Tl) collimated detector for non axis detector-source geometry has been calculated using a Monte Carlo approach from GEANT4 simulation code with 0.662 MeV of mono-energetic of photon gamma ray. Collimated Pb with 4 cm thickness and 2 cm of holes diameter were employed for shielding. The source was assumed as an isotropic point source and it is placed at various positions to the detector axis. The comparison between the measured energy response functions and the simulated energy response functions after normalization were also performed in order to validate the modeling results. © (2013) Trans Tech Publications, Switzerland.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Energy distributions,GEANT4,GEANT4 simulation,Isotropic points,Monte Carlo approach,Nai(Tl),Response functions,Scattering interactions[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Collimated detector,GEANT4,Monte carlo,Nai(Tl),Response function[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.4028/www.scientific.net/AMR.772.571[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]