Enter your keyword

2-s2.0-84896294028

[vc_empty_space][vc_empty_space]

One-step fabrication of short nanofibers by electrospinning: Effect of needle size on nanofiber length

Fathona I.W.a, Khairurrijalb, Yabuki A.a

a Graduate School of Engineering, Hiroshima University, Japan
b Department of Physics, Bandung Institute of Technology, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]The effect of needle inner diameter on the fiber length was studied and investigated. A polymer solution of cellulose acetate (CA) and organic solvent was ejected from various sizes of needle gauge then the electrospun polymer fibers were adhered on a collector plate. The diameter of fibers was ranging from 80 to 570 nm and the length could be controlled from 10 to 240 μm by increasing the needle inner diameter. The breakaway to shortened nanofibers occurred due to the imbalance of force from the surface tension of the polymer solution and the longitudinal force of the applied voltage. © (2014) Trans Tech Publications, Switzerland.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Applied voltages,Cellulose acetates,Collector plates,Electrospun polymers,Fiber length,Inner diameters,Longitudinal force,Nanofiber lengths[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Electrospinning,Needle gauge,Polymer,Short nanofiber[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.4028/www.scientific.net/AMR.896.33[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]