[vc_empty_space][vc_empty_space]
Heat loss model for flow assurance in a deep water riser
Soetikno D.a, Rodiah I.a, Islahuddin M.a, Kania R.A.P.a, Gunawan A.Y.a, Sukarno P.a, Permadi A.K.a, Soewono E.a
a Department of Petroleum Engineering, Institut Teknologi Bandung, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]The study is intended to investigate the heat loss phenomenon of oil flow in a riser. This heat loss happens due to the difference between the oil temperature in a riser and the surrounding sea water temperature. It causes the formation of wax that may disturb the flow. Heat loss can be reduced by setting up an insulator in a riser or by selecting appropriate pipeline specifications. It is necessary to determine the possible locations and specifications of insulator and pipeline. A mathematical model is formulated by considering the oil temperature and its flow velocity. Assuming that the density variation is small, the fluid behaves as an incompressible fluid. Furthermore, numerical solutions with finite difference methods are presented with some hypothetical data to give an overview of how the system works. Two surrounding conditions are taken into account, i.e. with and without sea current. From the simulation, the location of wax formation can be predicted. At a certain depth region of sea, where the sea current is present, a greater heat loss take place in which wax may be formed immediately. To overcome the formation of wax, we can control the parameters such as conductivity and wall thickness of pipe. © 2014 AIP Publishing LLC.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Deep Water,Density variations,Flow assurance,Heat loss models,Incompressible fluid,Navier Stokes,Numerical solution,Pipeline specifications[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]deep water riser,flow assurance,heat loss,mathematical modeling,Navier Stokes[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1063/1.4868856[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]