[vc_empty_space][vc_empty_space]
Influence of third harmonic injection signal on output current ripple and neutral current of three-level PWM inverter
Kastawan I.M.W.a, Harsoyo A.b, Hutabarat M.T.b, Dahono P.A.b
a Department of Energy Conversion Engineering, Politeknik Negeri Bandung, Bandung, Indonesia
b School of Electrical Engineering and Informatics, Institute of Technology Bandung, Bandung, 40132, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2015 School of Electrical Engineering and Informatics. All rights reserved.The influence of injecting third harmonic signal into three-phase sinusoidal reference signal of natural sampled PWM technique on output current ripple and neutral current of three-level inverter is analyzed in this paper. Expressions for both inverter output current ripple and neutral current as a function of PWM reference signal are derived first. Then, it is shown that injecting one fourth or twenty five percent third harmonic signal into three-phase sinusoidal reference signal may produce minimum output current ripple and neutral current. The twenty five percent third harmonic injection signal can simultaneously minimize output current ripple and neutral current of the three-level inverter only for unity power factor operation. Simulation and experimental results are included to show validity of the analysis results.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Current ripple,Neutral current,PWM technique,Third harmonic,Three-level inverter[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.15676/ijeei.2015.7.3.1[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]