[vc_empty_space][vc_empty_space]
Lightning protection system on overhead distribution line using Multi Chamber Arrester
Perdana E.a, Hidayat S.a, Zoro R.a
a Lightning Research Center, School of Electrical Engineering and Informatics, Bandung Institute of Technology, Bandung, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2014 IEEE.New innovation on arrester technology has been made by appearance of Multi Chamber Arrester (MCA). This kind of arrester has basic principle similar to previous technology which use air gap and air pressure in chamber as its technology. MCA has a function to protect overhead line from lightning. For instance, 20 kV medium voltage overhead line. Field testing has been set up to get analysis on MCA. Field testing has been done on 20 kV medium voltage overhead line of feeder Ruko of PLN Serpong. After a certain period of installation, line fault pattern of feeder Ruko is then captured to get the analysis. The analysis is used to get conclusions whether MCA is appropriate for lightning protection system on 20 kV overhead lines.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Air pressures,Basic principles,Field testing,Lightning protection systems,Line faults,Medium voltage overhead lines,Multi-chamber,Overhead distribution line[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]20 kV overhead line,line fault of feeder Ruko,Multi Chamber Arrester[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICPERE.2014.7067246[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]