Enter your keyword

2-s2.0-84946688823

[vc_empty_space][vc_empty_space]

Design, implementation and testing of triangle, circle, and square shaped loop antennas as partial discharge sensor

Rozi F.a, Khayam U.a

a Sekolah Teknik Elektro dan Informatika, Institut Teknologi Bandung, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2014 IEEE.This paper discusses the design and implementation of loop antena to measure partial discharge (PD). The loop antenna is designed to measure PD induced EM wave in the frequency up to 100 MHz. The form, the circumference, the number of rounds of loop antenna affect the frequency response of the antenna. In the design, the circumference of a loop antenna is set to be a tenth of a wavelength of PD induced EM wave. The conductor wire length of loop antenna is set to be 30 cm to achieve 100 MHz bandwidth. Various forms of the loop antenna: circle, square, and triangle have been designed and implemented. The designed loop antennas were applied to measure PD in high voltage laboratory. The needle-plate electrodes in air is used as a PD source. The test results showed that the new designed loop antennas were able to detect and measure PD. The sensitivity of the circle loop antenna is the best among the new designed loop antennas.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]circle,Design and implementations,High voltage laboratories,Needle plate electrodes,PD-induced EM wave,square,triangle,Wire length[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]circle,loop antenna,partial discharge,square,triangle[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICPERE.2014.7067219[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]