[vc_empty_space][vc_empty_space]
The induced current density calculation by charge simulation method for grounded and isolated man model exposed under 500 kV transmission line
Anggoro B.a, Qodir A.a
a School of Electrical Engineering and Informatics, Bandung Institute of Technology, Bandung, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2014 IEEE.The electric and magnetic fields always be produced by all electric apparatus and can induce the current induction in to human body. These induced current densities must be calculated/measured for determining the permission limit value of electric/magnetic fields, so we can define that the type of electric/ agnetic fields are dangerous to human being or not. The calculation of induced current densities in human body are done as result of electric field from 500 kV transmission line for grounded and isolated of man model, with the condition of ground surface without any tree or other object surronding the man model. Because of the character of model skin of the human body is conductive, so the result of this calculation for grounded and isolated is deference. For the grounded man model, the skin potential equals zero and the skin as equipotential surfaces. The illustration of the result are curved between induced current densities and section of the human body.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]500 kV transmission lines,Charge simulation methods,CSM,Electric and magnetic fields,Electric apparatus,Equipotential surfaces,Ground surfaces,Limit values[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]500 KV Transmission,CSM,induced current[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICEECS.2014.7045260[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]