[vc_empty_space][vc_empty_space]
Alternative method for testing overcurrent protection function by using least square method finding overcurrent function parameters without prior interrogation of relay setting
Panggabean J.S.a, Anggoro B.a
a School of Electrical Engineering and Informatics, ITB, Bandung, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2015 IEEE.A utility usually installed modern power system protection relays from multiple manufacturers and models. The testing of the relays is very challenging due to its complexity. This would increase expenses due to additional test duration and longer disturbance of power for the substation can’t be energized. Therefore a test that could be done without prior accessing the setting would be needed for faster on site test. In this study, the alternative test method and procedure for by passing the setting complexity was evaluated. The result of testing data of overcurrent protection function at optimum number of valid test points was processed to reveal the setting of the functions. The calculation provided the time multiplier setting, minimum pickup current and the curve of the setting. The result suggests a valid testing could be done without extracting preexisting function setting.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Function parameters,Least square methods,Optimum number,Over current,Pickup currents,Power system protection,relays,Time Multiplier Settings[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]overcurrent,power system protection,relays,testing[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICEEI.2015.7352496[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]