Enter your keyword

2-s2.0-84991517930

[vc_empty_space][vc_empty_space]

Inhomogeneity effect in Varian Trilogy Clinac IX 10 MV photon beam using EGSnrc and Geant4 code system

Yani S.a,b, Rhani M.F.c, Haryanto F.a, Arif I.a

a Department of Physics, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Bandung, 40132, Indonesia
b Akademi Kebidanan Pelita Ibu Kendari, Kendari, 90132, Indonesia
c Department of Radiation Oncology, National University Cancer Institute Singapore, Singapore, Singapore

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]Treatment fields consist of tissue other than water equivalent tissue (soft tissue, bones, lungs, etc.). The inhomogeneity effect can be investigated by Monte Carlo (MC) simulation. MC simulation of the radiation transport in an absorbing medium is the most accurate method for dose calculation in radiotherapy. The aim of this work is to evaluate the effect of inhomogeneity phantom on dose calculations in photon beam radiotherapy obtained by different MC codes. MC code system EGSnrc and Geant4 was used in this study. Inhomogeneity phantom dimension is 39.5 × 30.5 × 30 cm3 and made of 4 material slices (12.5 cm water, 10 cm aluminium, 5 cm lung and 12.5 cm water). Simulations were performed for field size 4 × 4 cm2 at SSD 100 cm. The spectrum distribution Varian Trilogy Clinac iX 10 MV was used. Percent depth dose (PDD) and dose profile was investigated in this research. The effects of inhomogeneities on radiation dose distributions depend on the amount, density and atomic number of the inhomogeneity, as well as on the quality of the photon beam. Good agreement between dose distribution from EGSnrc and Geant4 code system in inhomogeneity phantom was observed, with dose differences around 5% and 7% for depth doses and dose profiles.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Absorbing medium,Dose calculation,Dose distributions,Inhomogeneities,Radiation dose distribution,Radiation transport,Spectrum distribution,Water equivalent[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1742-6596/739/1/012117[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]