Enter your keyword

2-s2.0-84996520855

[vc_empty_space][vc_empty_space]

Design Study of 200MWth Gas Cooled Fast Reactor with Nitride (UN-PuN) Fuel Long Life without Refueling

Syarifah R.D.a, Yulianto Y.a, Su’ud Z.a, Basar K.a, Irwanto D.a

a Nuclear Physics and Biophysics Research Group, Department of Physics, Faculty of Mathematics and Natural Sciences, Bandung Institute of Technology, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© The Authors, published by EDP Sciences, 2016.Design study of 200 MWth Gas Cooled Fast Reactor with UN-PuN fuel long life without refueling has been done. GFR is one type reactor in Generation IV reactor system. It uses helium coolant and fast neutron spectrum. Helium is chemical inert, single phase and low neutron moderation. In this study the calculations are performed by using SRAC code with PIJ calculation for the fuel pin cell calculation and CITATION calculation for core calculation. The data libraries use JENDL 3.2. The variation fuel fractions are 50% until 60%. The diameter active core is 150 cm and the height active core is 100 cm. The reflector radial-axial width is 50 cm. The variation of the powers are 100 MWth up to 500 MWth. The high power causes the high k-eff value. The optimum design is reached when the power is 200 MWth, variation percentage Plutonium for fuel F1:F2:F3=9%:11%:13%. The comparation of fuel:cladding:coolant fraction = 55%:10%:35%. The cooling down time of Plutonium is nine months. The optimum k-eff value is 1.0142 with excess reactivity value 1.403%. The decay of Plutonium decrease k-eff value in the beginning of burn up.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Core calculations,Excess reactivity,Fast neutron spectrums,Gas cooled fast reactors,Generation IV reactors,Helium coolants,Neutron moderation,Optimum designs[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text]This work was supported by Decentralization Research Grand 2016, DIKTI, Ministry of Research Technology and Higher Education of the Republic of Indonesia which are gratefully acknowledged.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1051/matecconf/20168203008[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]