[vc_empty_space][vc_empty_space]
The prospect of uranium nitride (UN-PuN) fuel for 25- 100MWe gas cooled fast reactor long life without refuelling
Syarifah R.D.a, Su’Ud Z.a, Basar K.a, Irwanto D.a
a Nuclear Physics and Biophysics Research Division, Physics Department, Faculty of Mathematics and Natural Science, Bandung Institute of Technology Indonesia, Bandung, 40132, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© Published under licence by IOP Publishing Ltd.The prospect of uranium nitride (UN-PuN) fuel for 25-100MWe Gas Cooled Fast Reactor has been done. This research use helium coolant which has low neutron moderation, chemical inert and single phase. This study use natural uranium and plutonium. Plutonium taken from spent fuel of LWR (Light Water Reactor). So, it can reduced spent fuel in the world. The calculation use SRAC2006 and JENDL 4.0 for the data libraries. First, we calculate PIJ for fuel pin cell calculation and CITATION for core calculation. The reflector radial-axial width is 50 cm. The variation of fuel fraction is 40% until 65%, cladding 10%, and moderator 25% up to 50%. The variation of the power is 75-300 MWth (25-100 MWe). The calculation of survey parameter has been done. The variation of percentage plutonium is 7% up to 13%. We have optimum k-eff value in percentage of plutonium 11%. The high powers cause k-eff value high too. Second, the core configuration divided by three variation fuel (F1, F2, and F3). F1 is located in the central core, F2 middle core and F3 outer core. The variation percentage Plutonium for fuel F1:F2:F3 = 8%:10%:12%. The increasing power level make the burn up level increase. All case can reach burn up time plus than 20 years. The thermal powers increase cause the peak power density increase. The power 150 MWth, 225 MWth, and 300 MWth have excess reactivity (%Ak/k) less than 2%.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Core calculations,Core configuration,Excess reactivity,Gas cooled fast reactors,Natural uranium,Neutron moderation,Peak power densities,Uranium nitride[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1742-6596/776/1/012103[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]