[vc_empty_space][vc_empty_space]
The effect of X-ray micro computed tomography image resolution on flow properties of porous rocks
Latief F.D.E.a, Fauzi U.a, Irayani Z.b, Dougherty G.c
a Physics of Earth and Complex Systems, Faculty of Mathematics and Natural Sciences, Bandung Institute of Technology, Bandung, Indonesia
b Department of Physics, Jenderal Soedirman University, Purwokerto, Indonesia
c California State University, Camarillo, United States
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2017 The Authors Journal of Microscopy © 2017 Royal Microscopical SocietyThe study of digital rock physics has seen significant advances due to the development of X-ray micro computed tomography scanning devices. One of the advantages of using such a device is that the pore structure of rock can be mapped down to the micrometre level in three dimensions. However, in providing such high-resolution images (low voxel size), the resulting file sizes are necessarily large (of the order of gigabytes). Lower image resolution (high voxel size) produces smaller file sizes (of the order of hundreds of megabytes), but risks losing significant details. This study describes the effect of the image resolution obtained by means of hardware-based and software-based approach. Four samples of porous rock were scanned using a SkyScan 1173 High Energy Micro-CT. We found that acquisition using increased pixel binning of the camera (hardware-based resizing) significantly affects the calculated physical properties of the samples. By contrast, voxel resizing by means of a software-based approach during the reconstruction process yielded less effect on the porosity and specific surface area of the samples. However, the decreasing resolution of the image obtained by both the hardware-based and the software-based approaches affects the permeability significantly. We conclude that simulating fluid flow through the pore space using the Lattice Boltzmann method to calculate the permeability has a significant dependency on the image resolution.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Image pixel size,micro-CT,permeability,porosity,specific surface area,tortuosity[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1111/jmi.12521[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]