Enter your keyword

2-s2.0-85016585722

[vc_empty_space][vc_empty_space]

Solution concentration and flow rate of Fe3+-modified Porphyrin (Red Blood Model) on giant magnetoresistance (GMR) sensor efficiency

Aminudin A.a, Tjahyono D.H.b, Suprijadib, Djamal M.c, Zaen R.a, Nandiyanto A.B.D.a

a Department Fisika, Universitas Pendidikan Indonesia, Jawa Barat, Bandung, 40154, Indonesia
b Sekolah Farmasi, Institut Teknologi Bandung, Jawa Barat, Bandung, 40132, Indonesia
c Departemen Fisika, Institut Teknologi Sumatera, Lampung Selatan, 35365, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© Published under licence by IOP Publishing Ltd.Red blood has been of great interest for scientists since it relates to human’ and living creature’s life sustainability. One of the important compounds in red blood is porphyrin. Here, the purpose of this study was to develop a method for detecting porphyrin concentration using the assistance of giant magnetoresistance. In short of the method, we added Fe3+ solution to the porphyrin, and the mixed solution was introduced to the magnetic field. Next, the magnetized solution was introduced to the magnetic sensor to indicate the existence of porphyrin in the solution. To confirm the effectiveness of our method in detecting porphyrin, we varied the flow rate and concentration of Fe3+-modified porphyrin solution. The result showed that the more concentration and the slower flow rate affected the higher sensitivity gained. Since this developed method is simple but effective for detecting porphyrin concentration, we believe that further development of this method will be benefit for many applications, specifically relating to the medical uses.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Blood models,Concentration of fe,Giant magnetoresistances (GMR),Living creatures,Medical use,Mixed solution,Sensor efficiency,Solution concentration[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1757-899X/180/1/012137[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]