Enter your keyword

2-s2.0-85019262336

[vc_empty_space][vc_empty_space]

Analysis of lightning strike to overhead EHV 500 KV transmission system Jawa-Bali Crossing

Harijanto P.S.a, Zoro R.a

a Power Engineering Division, STEI-Institut Teknologi Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2016 IEEE.One of the technical problems in the construction of overhead lines 500 kV EHV transmission system Jawa-Bali Crossing is lightning disturbance. The most dominant problem is the height of the crossing tower (376 m) and high density of lightning strikes at the tower site. The potential disruption caused by lightning in the tower leads to insulator flashover on towers that can cause a loss of power flow at 500 kV line system. Calculation and analysis of each potential lightning disturbance at 500 kV EHV overhead lines can be used as an adequate reference to technical measures in designing protection against lightning strikes for the overhead lines 500 kV EHV transmission system Jawa-Bali Crossing.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]EHV transmission system,insulator,Insulator flashover,Lightning disturbances,Lightning strikes,Power flows,Technical measures,Transmission systems[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]EHV transmission system 500 kV,flashover,insulator,lightning disturbance[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICPERE.2016.7904880[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]