Enter your keyword

2-s2.0-85026799483

[vc_empty_space][vc_empty_space]

The evaluation of the effective diameter (Deff) calculation and its impact on the Size-Specific Dose Estimate (SSDE)

Anam C.a,b, Haryanto F.b, Widita R.b, Arif I.b, Dougherty G.c

a Department of Physics, Faculty of Mathematics and Natural Sciences, Diponegoro University Tembalang, Semarang, 50239, Indonesia
b Department of Physics, Faculty of Mathematics and Natural Sciences, Bandung Institute of Technology, Bandung, 40132, Indonesia
c Applied Physics and Medical Imaging, California State University, Channel Islands, United States

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2017 Atom Indonesia.Information on the effective diameter (Deff) is essential for estimating the dose for patients undergoing CT examinations. The purpose of this study was to calculate the effective diameter using the maximum values of lateral (LAT) and anteriorposterior (AP) diameters (Deff,m) and using LAT and AP diameters taken from the center of the image (Deff,c), and compare both estimates to the effective diameter calculated directly from the cross-sectional area of the patient (Deff,A). We evaluated 164 patients who underwent the four most frequent CT examinations, namely pelvic, abdominal, thoracic, and head examinations, using a multi-detector CT (MDCT), the Toshiba Aquilion 128. We used the Wilcoxon-Mann-Witney U test to statistically determine whether differences were significant. While Deff,m is statistically no different (p > 0.05) from Deff,A, Deff,c is statistically different (p < 0.05) from Deff,A except for head examinations.[/vc_column_text][vc_empty_space][vc_separator css=".vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_empty_space][megatron_heading title="Author keywords" size="size-sm" text_align="text-left"][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=".vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_empty_space][megatron_heading title="Indexed keywords" size="size-sm" text_align="text-left"][vc_column_text]CT scanner,Effective diameter (Deff),Size-specific dose estimate (SSDE),Supply some 4-6 keywords,Volume CT dose index (CTDIvol)[/vc_column_text][vc_empty_space][vc_separator css=".vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_empty_space][megatron_heading title="Funding details" size="size-sm" text_align="text-left"][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=".vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}"][vc_empty_space][megatron_heading title="DOI" size="size-sm" text_align="text-left"][vc_column_text]https://doi.org/10.17146/aij.2017.617[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]