Enter your keyword

2-s2.0-85030150597

[vc_empty_space][vc_empty_space]

Resistivtiy Structure in Tangkuban Parahu Area Drived from CSAMT Data

Mustopa E.J.a, Nurhasana, Srigutomo W.a, Sutarno D.a

a Earth Physics and Complex System Research Divison, Faculty of Mathematics and Natural Sciences, Bandung Institute of Technology, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© Published under licence by IOP Publishing Ltd.Tangkuban Parahu is located in Bandung, West Java, one of a volcano area. Controlled-source audio frequency magnetotelluric (CSAMT) survey has been conducted in the area using transmitter located in 3-5 km from the survey area. The objective of the survey was to determine a subsurface resistivity structures that may correlate to a geothermal reservoir in unknown geothermal potential area. In the paper, we applied a two-dimensional (2D) inversion scheme to interpret of the CSAMT data to obtain several resistivity sections describing the subsurface resistivity structures. The results of 2D inversion indicated several subsurface low resistivity anomaly (1-10 ohm.m) in the depth of 1000-1500 meter that may correlate to the existing a geothermal reservoirir confirmed by several surface manifestations in the area.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Audio frequencies,Controlled source,Geothermal potential,Geothermal reservoir,Inversion scheme,Resistivity structure,Surface manifestations,Two Dimensional (2 D)[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text]The authors are grateful to Penelitian Unggulan Perguruan Tinggi Ristek-Dikti for funding of the[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1742-6596/877/1/012055[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]