Enter your keyword

2-s2.0-85041683064

[vc_empty_space][vc_empty_space]

Alternative Intake Station in Saguling Reservoir for the Needs of Raw Water in Bandung Metropolitan Area

Marselina M.a, Sabar A.a, Salami I.R.S.a, Marganingrum D.b

a Faculty of Civil and Environmental Engineering, Institut Teknologi Bandung, Indonesia
b Indonesian Institute of Science, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© The Authors, published by EDP Sciences, 2018.Bandung Metropolitan Area (BMA) region is the upper watershed of Citarum with an area of ± 2338 km2. The status carried by BMA as a National Strategic Area from the perspective of economic encourage the increasing migration flows to BMA. These circumstances lead to an imbalance between supply and demand, in which on the one hand, demand for clean water is increasing. The potency of Saguling Reservoir as an alternative of raw water of BMA region in terms of quantity in this research was determined based on the determination of mainstay discharge. In this study, the intake site selection 11 monitoring posts will be carried out by reviewing the concentration of all parameters in Government Regulation No. 82 Year 2001 on any division of discharge grade using 5-grade Makov Discrete method (very dry, dry, normal, wet and very wet). In addition, the calculation of the value of Water Quality Index (WQI) was done at each monitoring station for each division of discharge grade that has been done. The series of data flow and concentration parameters used in this study start from the year 1999 to 2014. The allocation of raw water discharge calculation for Saguling Reservoir in order to fulfill the needs of raw water in Bandung Metropolitan Area is 46,92m3/second (R5 dry for irrigation raw water supply and 29,53 92 m3/second (R10 dry for drinking water supply). Based on the assessment of the concentration of measured parameters and determination of Water Quality Index, it can be found that around Muara Ciminyak location is the most qualified location to be used as drinking raw water intake for Bandung Metropolitan Area. Based on this study, it also notes that the determination of the concentration of pollutant parameters needs to be done on the each division of discharge grade occurred.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Government regulation,Measured parameters,Metropolitan area,Monitoring stations,Pollutant parameters,Raw water supply,Supply and demand,Water quality indexes[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1051/matecconf/201814703015[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]