Enter your keyword

2-s2.0-85042750609

[vc_empty_space][vc_empty_space]

Damper winding analysis on synchronous generator 10625 KVA in short circuit condition

Setiyoso A.a, Purwadi A.a, Haroen Y.a

a Dept. of Electrical Engineering, School of Electrical Engineering and Informatics, ITB, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2017 IEEE.The value of sub-transient reactance depends on the design of damper winding or amortissuer. All synchronous generators have sub-transient reactants even though it does not have damper winding physically. The damper winding can contribute to reduce the sub-transient current when generator in fault condition. The generator quantitative parameters are used to perform the simulation using MATLAB/Simulink to determine the fault current that will occurs and also to predict the magnitude of current that flows on the damper winding. In this study, the analysis of the generator is performed using Park dq0 system.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Amortisseur,Damper windings,Fault conditions,MATLAB /simulink,Quantitative parameters,Short-circuit conditions,Simulation,Transient current[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Amortisseur,Damper winding,Simulation,Sub-transients,Synchronous generator,Transient[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICHVEPS.2017.8225872[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]