[vc_empty_space][vc_empty_space]
Design of ultrawide band partial discharge detector using Pi attenuator and ultrawide band amplifier
Furqon D.a, Putra R.S.a, Khayam U.a
a School of Electrical Engineering and Informatics, Bandung Institute of Technology, Bandung, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2017 IEEE.Detection of partial discharge (PD) in the frequency range ultrawide band (UWB) provides some benefits such as in a more accurate observation of the PD pulse shape and the PD frequency spectrum. One method to measure the PD signals in the UWB frequency range is by using the PD detecting impedance circuit. The 50 ohm detecting impedance is used as a coupling device to maximize power transfer of PD current. This paper design the matching impedance circuit comprising an impedance detector as attenuator and UWB amplifier as a signal amplifier. S-parameter characteristics of the circuit is simulated in software Advanced Design System (ADS) software. The PD detecting circuit is made and it is tested using Vector Network Analyzer (VNA) instruments. Then, the circuit is used to measure PD on the needle -plates electrode in the air.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Advanced design system softwares,Coupling devices,Detecting circuit,Frequency spectra,Impedance circuits,Impedance detectors,Partial discharge detectors,Vector network analyzers[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Coupling device,Matching impedance,Partial discharge,Ultrawide band amplifier[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ISITIA.2017.8124052[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]