[vc_empty_space][vc_empty_space]
FPGA based hardware implementation of fault detection for microgrid applications
Ramadhan S.a, Hariadi F.I.a, Ahmad A.S.a
a School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Microelectronic Center, Institut Teknologi Bandung, Bandung, 40132, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2017 IEEE.This paper describes hardware implementation for fault detection on a power grid using FPGA. The fault detector implements a Haar wavelet algorithm to detect the fault, the fault is indicated by a change of phase angle and amplitude on sinusoidal wave. Sinusoidal wave on the grid must be sampled into a digital value using an analog to digital converter (ADC), then the ADC’s value transferred into a wavelet block in the FPGA. The wavelet block in FPGA will calculate the data measured by ADC using Haar wavelet algorithm, and detect the fault by change in the ADC’s sampling value. The calculation of Haar wavelet implements a systolic array processor, and the data fault simulation will be generated by a modelling software.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Analog to digital converters,Digital values,Fault detector,FPGA-based hardware implementation,Hardware implementations,Modelling softwares,Sampling values,Sinusoidal wave[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Fault Detection,Wavelet Hardware Implementation,Wavelet Transform[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ISESD.2017.8253323[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]