Enter your keyword

2-s2.0-85050795570

[vc_empty_space][vc_empty_space]

Design and application of loop antenna for partial discharge induced electromagnetic wave detection

Khayam U.a, Fatoni F.I.a

a School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2017 IEEE.Power apparatus is generally in the form of metal enclosed equipment. The released energy from PD such as light, heat, and EM wave is disable to pass through metal enclosure, so it must be detected by the internal sensor. However, PD induced EM wave may leak from the dielectric window of power apparatus. EM wave may propagate through the dielectric window and detected by external sensor. The PD measurement by using external sensor has many advantages such as safe and easy in sensor installation. Therefore, the PD measurement system in metal enclosed equipment will be developed based on EM wave induced by PD detected by external sensor. First, the sensors which be able to detect PD induced EM wave in ultrawide band need to be designed and manufactured. Second, the characteristics of PD induced EM wave measured by the sensors need to be investigated. This paper deals with design and application of loop antenna for partial discharge (PD) induced electromagnetic (EM) wave detection in power apparatus. The loop antenna was designed to measure PD induced EM wave in power apparatus.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Design and application,Dielectric windows,External sensors,Internal sensors,Metal enclosure,Partial discharge induced electromagnetic wave,PD-induced EM wave,Sensor installation[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]electromagnetic wave,loop antenna,partial discharge[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICEEI.2017.8312341[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]