[vc_empty_space][vc_empty_space]
Enveloping partial discharge signal using direct interpolation method
Zaeni A.a, Khayam U.a
a School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, 40132, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2017 IEEE.Partial Discharge (PD) is one of parameter that show the condition of insulator in power aparatus. Partial discharge (PD) waveform which is measured by UHF PD measurement system contain high frequency noise. So that we find any difficulties to ensure that the wave which we get is PD signal. The PD waveform parameters such as rise time and fall time also are difficult to be calculated. Moreover the determination of number and magnitude of PD pulse is also difficult to be analyzed. One of method that we can do to analyze UHF waveform from PD is enveloping that signal. So that we can get wave in lower frequency form which make us easy to find important quantities from that pulse such as rise time, fall time, pulse width, and peak voltage. We can make enveloping system by direct interpolation method which processing the data from csv files obtained in the measurement that is integrated with the computer.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Fall time,Peak voltage,Pulsewidths,Risetimes,Wave forms[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]direct interpolation,fall time,partial discharge,peak voltage,pulse width,rise time,waveform[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICEVT.2017.8323535[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]