Enter your keyword

2-s2.0-85054510327

[vc_empty_space][vc_empty_space]

Experimental Investigation and Numerical analysis of SO2 Removal Using Polypropylene Membrane Contactor

Ariono D.a, Hakim A.N.a, Wenten I.G.a

a Chemical Engineering Department, Institut Teknologi Bandung, Bandung, 40132, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© Published under licence by IOP Publishing Ltd.In this study, polypropylene membrane contactor is designed for SO2 absorption of simulated flue gas. Water and the aqueous solution of Na2SO3 are used as an absorbent. Absorption performance of the longitudinal module is compared to novel transversal membrane contactor module. The result shows that the transversal configuration of hollow fiber module significantly enhances absorption performance over conventional longitudinal configuration. Absorption flux of SO2 in aqueous Na2SO2 is 1.8 times higher than water at optimum Na2SO3 concentration and gas flow rate. According to performance stability test, polypropylene hollow fiber membrane is successfully operated for 15 hours maintaining average absorption flux of 20 x 10-5 mol.m-2.s-1. Numerical simulation shows good agreement with physical absorption data.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Absorption performance,Experimental investigations,Hollow fiber module,Membrane contactor,Performance stability,Physical absorption,Polypropylene hollow fiber membrane,Polypropylene membrane[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1742-6596/1090/1/012008[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]