[vc_empty_space][vc_empty_space]
Building Retrofit to Improve Energy Performance from Office to Accommodation. Case study: Tower Building, Nottingham, UK
Ardiani N.A.a, Suhendria, Koerniawan M.D.a, Budiarto R.b
a Department of Architecture, Institut Teknologi Bandung, Bandung, Indonesia
b Department of Nuclear Engineering and Engineering Physics, Universitas Gadjah Mada, Yogyakarta, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© The Authors, published by EDP Sciences, 2018.Designed in Brutalism style by architect Andrew Renton, Tower Building has 17 floors for academic and lecturers’ office function. As the highest point in University of Nottingham, this tower has been built for almost five decades. The aim of this project is to propose the tower retrofit from current function to accommodation purpose. Improvement in terms of function and building energy performance by applying sustainable building technologies are the objectives of the retrofit. The advanced plan of building retrofit was proposed after assessing the current building performance and determined the problems. The proposed building design was based on building performance simulation result, literature, and precedent studies. Thereafter, several technologies and design ideas were applied for further investigation, to examine how is the strategies works in the building retrofit. Integrated double skin façade with BIPV, bio composite material for internal wall, double low-e glass for external wall, as well as green lung to improve natural ventilation and create public space were proposed for the building.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Biocomposite materials,Building energy performance,Building performance,Building performance simulations,Energy performance,Natural ventilation,Sustainable building,University of Nottingham[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text]This building retrofit study was part of the Sustainable Research Project course in the MSc Sustainable Building Technology Program at the University of Nottingham. We gratefully acknowledge the funding from USAID in Sustainable Higher Education Research Alliances (SHERA) program through Centre for Development of Sustainable Region (CDSR).[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1051/matecconf/201820602010[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]