Enter your keyword

2-s2.0-85056456252

[vc_empty_space][vc_empty_space]

Sound insulation design improvement for reducing noise of paper factory office

Kanteyan M.S.a, Utami S.S.a, Prasetiyo I.b, Yanti R.J.a

a Department of Nuclear Engineering and Engineering Physics, Universitas Gadjah Mada, Yogyakarta, Yogyakarta, Indonesia
b Department of Engineering Physics, Institut Teknologi Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© Published under licence by IOP Publishing Ltd.Noise exposure in industrial building such us a paper production factory can be harmful for the employees whom are working in the outdoor area as well as in the offices. Some employees that are working in the open-plan office area in this factory layout are complaining about the noise produced by machines. The noise produced from the machines makes them hard to focus on their jobs. It is found that the closest noise source position from the office produces 79 dBA while the noise level of 54 dBA is present in the office. To deal with this situation, a noise mapping was done using Sound Level Meter (SLM) for measurement. The noise mapping can help for noise assessment to know the noise distribution in the factory that give an impact to office. The Transmission Loss (TL) of the office walls was evaluated by measuring the noise level spectrum inside and outside of the office, while T30 (reverberation time) values were also measured to obtain for room absorption assessment as it affects the TL values. These two parameters used to obtain the Sound Transmission Class (STC). It also enables to systematically predict the sound insulation improvement of the offices particularly as a basis to choose suitable material and wall construction. In this research, INSUL software is utilized to calculate the TL of the proposed wall design. The result shows that improvement of existing partition insulation using double glazing laminated glass and gypsum can meet the preferable noise level inside of the office that is 38 dBA using the new STC value of 23.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Industrial buildings,Insulation design,Noise distribution,Open-plan offices,Reverberation time,Sound level meter,Sound transmission,Wall construction[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1742-6596/1075/1/012060[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]