Enter your keyword

2-s2.0-85059417649

[vc_empty_space][vc_empty_space]

Low-Cost Pressure Sensor Matrix Using Velostat

Suprapto S.S.a, Setiawan A.W.a, Zakaria H.a, Adiprawita W.a, Supartono B.b

a Sekolah Teknik Elektro dan Informatika, Institut Teknologi Bandung, Bandung, Indonesia
b Medical Faculty, UPN Veteran Jakarta, Jakarta, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2017 IEEE.This paper presents a characteristic of a 32×32 sensor matrix based on velostat for foot pressure distribution measurements. The sensor has been constructed of dual electrodes placed on the top and underneath velostat as the sensing material. The experimental results show the sensor matrix has relatively linear in Force-Conductance response until 15 N. The system evaluation stage was obtained by comparing the sensor matrix with several other methods implemented in RSON and obtained the performance of the sensor matrix in the form of the comparison of the footprint area with the error value of 7.3% to 68.8%, the average pressure of 7.3% to 68.8%, the maximum pressure 37.6% to 70.7%, body weight of 0.4% to 12.1%, and arch-index with a specificity value of 0.3 and a sensitivity of 0.5.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Distribution measurement,Dual electrodes,Foot pressures,Maximum pressure,Sensing material,Sensor matrix,System evaluation,Velostat[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Crosstalk,Pressure Sensor Matrix,Velostat[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICICI-BME.2017.8537720[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]