[vc_empty_space][vc_empty_space]
Development of non-occlusive blood pressure monitor with height correction for home used application
Setiawan A.W.a, Heryanto N.A.a, Putra F.M.a, Suyitno F.a, Andre Martin M.b, Raharja Y.S.b, Sayyid Hashuro M.S.a,c
a School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Indonesia
b Qimtronics, Bandung, Indonesia
c Department of Finemechanics, Institute of Fluid Science (IFS), Tohoku University, Sendai, Japan
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2019 Institute of Advanced Engineering and Science. All rights reserved.Non-occlusive blood pressure measurement method is developed to avoid the use of discontinuous and uncomfortable cuff-based methods. In this research, Pulse Transit Time (PTT) and Photoplethysmogram Intensity Ratio (PIR) is used to measure blood pressure. Two photoplethysmogram (PPG) sensors that are placed on the wrist and one of the finger joints both on the left hand is used to get the PTT and PIR. The name of the device is ARTSEN. During measurement, there is a measurement error caused by the hydrostatic effect when the device position is not inline with the heart. To minimize this error, this research proposes an automatic continuous blood pressure monitor. The device will conduct measurement only when the height of the device is inline with the heart. Accelerometer and gyroscope are used to detect the height of the device. There are 30 subjects that are involved in this research. To evaluate the performance of the device, there are two measurement conditions, during lying in the bed and sit down position. The blood pressure measurement is conducted using ARTSEN and sphygmomanometer (as the gold standard). The average error of systolic blood pressure is 8 mmHg with standard deviation 5 mmHg, and average error of diastolic blood pressure is 8 mmHg with standard deviation 4 mmHg.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Non-occlusive blood pressure,PPG intensity ratio,Pulse transit time,Relative height correction[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.11591/ijeecs.v14.i2.pp921-928[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]