Enter your keyword

2-s2.0-85063567789

[vc_empty_space][vc_empty_space]

Subsea pipeline protection design subjected to dropped anchor using concrete mattress

Tawekal R.L.a, De Velas J.a

a Offshore Engineering Research Group, Ocean Engineering Program, Institut Teknologi Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© Int. J. of GEOMATE.Out of the many potential hazards, certain critical possible hazards need to be assessed, and actions need to be taken to improve the probabilities and consequences to an acceptable degree. One of the major hazards commonly found in subsea pipeline operations is a dropped anchor, especially for pipelines located near jetties, where many ships are expected to move across the pipeline. One of the possible protection methods is the use of a concrete mattress. The dropped anchor hazard to a pipeline is characterized by the impact of energy, which will mostly be absorbed by the internal strain energy of the pipeline. The safety criteria for a pipeline subjected to a dropped anchor are given by DNV RP-F107 for the maximum dent depth and DNV OS-F101 for the maximum stress. A finite element analysis using ANSYS software was performed to obtain the maximum equivalent stress and dent depth for a pipeline. The effects of the length and height of a concrete mattress in redistributing the impact energy were obtained.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Concrete mattress,Dropped anchor,Finite element analysis,Subsea pipeline[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.21660/2019.60.84652[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]