Enter your keyword

2-s2.0-85065620079

[vc_empty_space][vc_empty_space]

Process control of milk pasteurization using Geothermal brine under Geothermal brine temperature and flow rate disturbance

Widiatmo J.S.a, Hendrarsakti J.a

a Institut Teknologi Bandung, West-Java-Bandung, 40132, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© Published under licence by IOP Publishing Ltd.Geothermal brine can be used as a heating liquid for pasteurization unit either by directly use the brine to heat up the raw milk, or by heating secondary fresh water. The geothermal brine can be obtained directly from geothermal well or from geothermal power plant separator. Unlike conventional pasteurization, the flow rate and temperature of geothermal brine might fluctuate due to many factors such as rain, well decline, and well shut down. Inherently the geothermal reservoir tends to decline in pressure and temperature. If the geothermal brine is obtained from geothermal power plant, then the flow rate and temperature of geothermal brine itself is susceptible to many changes in plant’s operation. A control system is needed for such utilization of geothermal brine. Simulation has been carried out to study the effect of PID feedback controller under geothermal brine temperature and flow rate disturbance. The result shows that PID controller could be used to compensate such disturbance. The PID controller controls milk inlet flow rate to balance the effect of both disturbances.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Fresh Water,Geothermal brines,Geothermal reservoir,PID controllers,PID feedback,Plant’s operation,Pressure and temperature,Raw milk[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1755-1315/254/1/012018[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]