Enter your keyword

2-s2.0-85071600487

[vc_empty_space][vc_empty_space]

Optimization of pyrrole electropolymerization on a steel gauze electrode using the cyclic voltammetry method

Sukmawardani Y.a,b, Ihsanawatia, Bucharia

a Department of Chemistry, Faculty of Mathematics and Sciences, Institut Teknologi Bandung, Bandung, Indonesia
b Department of Educational Chemistry, Universitas Islam Negeri Sunan Gunung Djati, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2019 Trans Tech Publications Ltd, Switzerland.Study on pyrrole electropolymerization is the preliminary step in synthesizing polypyrrole membranes, which can be used for various purposes in biosensor. In this work, electropolymerization process and electrochemical analysis of polypyrrole as an electroactive polymer have been studied by cyclic voltammetry. Pyrrole was electropolymerized to form polypyrrole in an aqueous potassium chloride solution at different pHs using phosphate buffer. The results showed that a potential range of 0-1200 mV is suitable for polypyrrole electropolymerization using the Ag|AgCl electrode as the reference. The formation of polypyrrole is stable at a scan rate of 100 mV/s. In addition, the optimized pyrrole electropolymerization was obtained using 0.1 M pyrrole and phosphate buffer at pH of 2-6. Taken together, this study can be used as a reference for the synthesis of other conducting polymers.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Aqueous potassium chloride,Electro-active polymers,Electrochemical analysis,Other conducting polymers,Phosphate buffers,Potential range,Scan rates,Votammetry[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Biosensor,Cyclic votammetry,Electropolymerization,Immobilized α-amylase,Polypyrrole[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.4028/www.scientific.net/KEM.811.133[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]