Enter your keyword

2-s2.0-85071863914

[vc_empty_space][vc_empty_space]

The effect of atrazine concentration on galvanic cell potential based on molecularly imprinted polymers (MIPS) and aluminium as contact electrode

Royani I.a, Assaidaha, Widayanib, Abdullah M.b, Khairurrijalb

a Dept. of Physics, Faculty of Mathematics and Natural Sciences, Sriwijaya University, Indonesia
b Nuclear Physics and Biophysics Research Division, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© Published under licence by IOP Publishing Ltd.Potentiometric sensors had been fabricated by employing the Atrazine MIPs as the working electrode; Aluminum (Al) as the electrode potential. A glass with diameter 3 mm and 6 mm as the vessels for chemical solution. The sensor target was a test solution of Atrazine with different concentration. The potential measured between the electrode contact and reference were increase by the rise of Atrazin concentration. The graph of potential cell versus logarithm of concentration revealed two slopes for Al contact. It implied that the potentiometric sensor was sensitive in the range of concentration 0.44-0.55 mM. Reevaluation of the sensor was conducted 3 months later by following the same procedure. Still, the graph showed a consistent curve that prove sensor stability.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Atrazine concentrations,Chemical solutions,Contact electrodes,Electrode contacts,Electrode potentials,Galvanic cells,Molecularly Imprinted Polymer,Working electrode[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1742-6596/1282/1/012029[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]