Enter your keyword

2-s2.0-85073979346

[vc_empty_space][vc_empty_space]

Characterising thermal behaviour of buildings and its effect on urban heat island in tropical areas

Wonorahardjo S.a, Sutjahja I.M.a, Mardiyati Y.b, Andoni H.a, Thomas D.a, Achsani R.A.a, Steven S.b

a Building Technology Research Group, SAPPK, ITB, Bandung, 40132, Indonesia
b Materials Engineering Department, FTMD, Bandung, 40132, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2019, The Author(s).The heat island phenomenon in major cities is partly due to the excessive use of concrete and brick, which causes many problems regarding thermal comfort and energy expenditure. The thermal behaviour of the envelope wall material depends on its density, heat capacity, and thermal conductivity, and its effect on the heat island intensity (HII) is reported in this paper. Experiments and simulations were carried out on the four most popular building materials: brick, aerated concrete, wood with glass-wool insulation, and glass fibre-reinforced concrete with glass-wool insulation, with each material having a dimension of 1 m × 1 m. Experiments to analyse the thermal behaviour of the wall materials were performed by exposing each material to heat radiation from 2 × 1000 W halogen lamps for 4 h, followed by 4 h of cooling. The HII simulations were carried out in a simple urban kampong in a tropical area using Energy2D software. Heat flow analyses confirmed the thermal behaviour of the four walls, which can be categorised into two types: heat storage of block wall (BW) type and heat flow inhibition of insulated sandwich wall (ISW) type. The BW type showed 0.32 °C higher indoor air temperature than the ISW type, while the HII simulation showed ISW to be 0.74 °C higher than BW; however, both types increase the intensity and need mitigation treatment. The results of this study are important for the technological approach for dealing with local warming to lower the energy expenditure of poor people in an urban area.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Block walls,Insulated sandwich wall,Thermal behaviours,Urban heat island,Urban kampong[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Block wall type,Insulated sandwich wall,Thermal behaviour,Urban heat island,Urban kampong[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text]We thank all those people who prepared the samples and equipment, especially Suwardi Tedja who prepared the test sample. This research and publication are fully funded by the ITB through the 2018 Multidisciplinary research scheme with Contract No. 074a/I1.C10/KU/2018.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1007/s40095-019-00317-0[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]