[vc_empty_space][vc_empty_space]
Tropical lightning current parameters and protection of transmission lines
a Lightning Research Center (LRC), School for Electrical Engineering and Informatics (SEEI) Institute of Technology Bandung (ITB), Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2019, School of Electrical Engineering and Informatics. All rights reserved.Lightning Parameters in tropical area have a significant different against Lightning Characteristic measured in the subtropical area. Eight-years measurement has been done at Lightning Measurement Station in Mnt. Tangkuban Perahu to derive the lightning current characteristic in the tropic and it influence to the performance of the transmission lines against lightning strike. Indonesian state electricity company and other private company in Indonesia supply their electricity power using high voltage and extra high voltage transmission lines. To protect these transmission lines against lightning strikes, conventional lightning protection system are used. Due to their different lightning characteristic, the damage on the insulators on transmission towers, earth wire and transmission lines arrester that lead to power system outages are reported. Some innovative technology based on researches carried out in Lightning Measurement Station in Mnt Tangkuban Perahu and several research areas in Indonesia are now installed to improve the lightning protection in transmission lines. Some significant improvements are reported.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Conventional protection system,Extended mast terminal,Insulator damages,Lightning current parameters[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.15676/ijeei.2019.11.3.4[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]