Enter your keyword

2-s2.0-85074946210

[vc_empty_space][vc_empty_space]

Comparison of Fetal Heart Rate Detection Using Envelope Extraction and Shannon Energy

Setiawan A.W.a, Sujatmiko W.a

a Biomedical Engineering Research Group, School of Electrical Engineering and Informatics, ITB, Bandung, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2019 IEEE.Heart rate monitoring is widely used as a general procedure to examine fetal health condition. Fetal heart rate can be used to identified possibilities of fetal anomaly and warn the obstetrician to provide immediate intervention before any further abnormalities. The purpose of this research is to compare fetal heart rate detection result using envelope extraction and Shannon energy envelope method. There are 115 fetal phonocardiography and maternal phonocardiography that is used in this research. The dataset was obtained from Hafez Hospital, Shiraz University of Medical Science. Envelope extraction method can be used to detect fetal heart rate signal with 89.2% accuracy for all fetal phonocardiography signal while Shannon energy envelope method can be used to detect fetal heart rate signal with 88.3% accuracy for all fetal phonocardiography signal.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Envelope extraction,Fetal anomalies,Fetal heart rate,Fetal phonocardiography,Health condition,Heart-rate monitoring,Medical science,Shannon[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Envelope extraction,Fetal heart rate,Fetal phonocardiography,Shannon energy[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ISEMANTIC.2019.8884227[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]