[vc_empty_space][vc_empty_space]
Analysis of Waveform of Partial Discharge in Oil Insulation Measured by RC Detector
Sinurat M.S.a, Khayam U.a
a School of Electrical Engineering and Informatics, Institut Teknologi Bandung, Bandung, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2019 IEEE.The damage of power apparatus is caused mainly by the insulation problems initiated by the presence of partial discharge (PD) inside the insulation. PD measurement is one of the method to know the quality of the insulation of power apparatus. PD signal is displayed as PD waveform, PD pattern, and PD pulse sequences. This study discusses analysis of waveform of PD in oil insulation measured by RC detector. The electrode used is a needle-plate electrode with a distance of 1 cm. Background noise (BGN), PD inception voltage (PDIV) and PD waveforms were measured. The measurement result show that negative PDIV is 3.55 kV and positive PDIV is 4.01 kV. Negative and positive PD waveforms are measured at 16 kV, 16.5 kV, 17 kV, 17.5 kV and 18 kV. The rise time, fall time, and the peak to peak of PD waveforms at some voltage levels were analyzed.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Analysis of waveform,Background noise,Needle plate electrodes,Oil insulations,PD inception voltage,PD measurements,Power apparatus,Wave forms[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]oil insulation,partial discharge,RC detector,waveform[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICA.2019.8916760[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]