[vc_empty_space][vc_empty_space]
Development of a new personal air filter test system using a low-cost particulate matter (PM) sensor
Hapidin D.A.a, Munir M.M.a, Suprijadia, Khairurrijal K.a
a Department of Physics, Faculty of Mathematics and Natural Sciences, Institut Teknologi Bandung, Bandung, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2020, © 2020 American Association for Aerosol Research.The extensive use of air filters has encouraged advances in both the fabrication and characterization of air filter technology. An affordable and accessible means of assessing the quality of air filters is greatly needed because of the high demand for these filters. We developed a personal air filter test (PAFT) system for measuring filter pressure drop, efficiency, and quality of filtration. The PAFT system utilizes a PM sensor (Sharp, GP2Y1010AU0F) to measure filtration efficiency. PM sensor performance was evaluated and optimized to guarantee its suitability for this application. The sensor performance evaluation studied the output responses to sampling flow, particle diameter, and PM sources. We also improved the sensor’s sensitivity. The experimental results show that the sensor had no significant influence on the sampling flow. The sensor output was highly dependent on the particle size and PM source, but its response curves remained linear, which was an advantage for filter efficiency measurement. We measured the efficiency of nanofiber filters of various efficiencies, comparing the results to a reference efficiency as measured by a CPC (TSI, 3772). The test resulted in a filtration coefficient (Kf), which was used to correct the PAFT efficiency measurement results. We also conducted filtration efficiency tests on commercial mask filters and the results showed good agreement to the reference, with a small average error of about 2.5%. The complete design of the PAFT and experimental methods is discussed in detail. Copyright © 2020 American Association for Aerosol Research.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Efficiency measurement,Experimental methods,Fabrication and characterizations,Filtration coefficient,Filtration efficiency,Jing Wang,Particle diameters,Sensor performance[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Jing Wang[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text]D.A.H. gratefully acknowledges the Ministry of Research, Technology, and Higher Education Indonesia for the provision of a master leading to doctoral scholarship (PMDSU). The authors thank Prof. Kikuo Okuyama, Prof. Takafumi Seto, and Dr. Eng. Ferry Iskandar for providing LDMA and SMAC apparatus. D.A.H. thanks Widya Sinta Mustika, M.Si. and Iswanti Sihaloho, S.Si. for their technical support during the experiment.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1080/02786826.2019.1678734[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]