Enter your keyword

2-s2.0-85078476225

[vc_empty_space][vc_empty_space]

Numerical and Experimental Study of Thermal Response of an Electrified Nickel Wire

Lubis N.F.a, Widartiningsih P.M.a, Viridi S.a

a Department of Physics, Faculty of Mathematics and Natural Science, Bandung Institute of Technology, Bandung, 40132, Indonesia

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© Published under licence by IOP Publishing Ltd.An electrified nickel wire can produce heat. The heat is transferred to the environment around the wire radiation. However, the temperature produced by the wire will differ depending on the number of voltages supplied by the power source. Here, we do an experiment to measure the temperature of stand-up wire at each voltage of 4.5 V, 6.0 V, 7.5 V, 9.0 V, and 12 V. As a comparison, numerical measurements are done by JavaScript program. We show that the highest temperature of the wire approaches 314 K at 12 V. To equalize the temperature in both methods, the numerical scale factor of time and current in numerical measurements are changed according to the voltage. As a result, temperatures produced in both methods have minimal gap difference with error percentage below 0.5%. In conclusion, the experiment results were used to determine the scaling parameters to approach the ideal thermal response curve in actual values.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Error percentage,Highest temperature,JavaScript programs,Numerical and experimental study,Power sources,Scale Factor,Scaling parameter,Thermal response[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1742-6596/1397/1/012006[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]