[vc_empty_space][vc_empty_space]
The Step of Partial Discharge Pattern Recognition Using Fuzzy Logic
Lumba L.A.a, Khayam U.a, Lumba L.S.a, Dewanata Widjaja C.a
a Institut Teknologi Bandung, School of Electrical Engineering and Informatics, Bandung, Indonesia
[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2019 IEEE.This paper discusses the method of detecting and measuring Partial Discharge using fuzzy logic. Most of insulation failures indicate Partial Discharge (PD) activity prior to the fault. Several cases show PD is the indication of insulation aging and also the cause of insulation deterioration. Further effect of PD is accelerating the insulation breakdown to occur. Many researches conclude that monitoring is important to be performed. Monitoring PD can avoid the high voltage equipment experience an early aging. Detecting PD is necessary to know the amount of PD and understand the condition of the equipment. The measurements are made using electrical methods for air insulation. The measurement results will be conducted on three level of voltages, and the results will be compared to determine the effectiveness of fuzzy logic in determining the state of the apparatus and monitoring partial discharge.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Air insulation,Electrical methods,High-voltage equipments,Insulation aging,Insulation breakdown,Insulation deterioration,Insulation failures,Partial discharge pattern recognition[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Air Insulation,and RC Detector sensor,Fuzzy Logic,Partial Discharge (PD)[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1109/ICHVEPS47643.2019.9011078[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]