Enter your keyword

2-s2.0-85085582728

[vc_empty_space][vc_empty_space]

Simulation of VMAT (Volumetric Modulated Arc Therapy) Delivery techniques on Cylinder Phantom Based on DICOM Data using Monte Carlo Method – EGSnrc

Ramdani R.a, Kurniawati D.a, Perkasa Y.S.a, Subkhi M.N.a, Syajaah K.N.a,b, Rhani M.F.c, Haryanto F.b, Yani S.b

a Department of Physics, Faculty of Science and Technology, Uin Sunan Gunung Djati, Bandung, Indonesia
b Department of Physics, Faculty of Mathematic and Natural Science, Institut Teknologi, Bandung, Indonesia
c Tan Tock Seng Hospital, Singapore

[vc_row][vc_column][vc_row_inner][vc_column_inner][vc_separator css=”.vc_custom_1624529070653{padding-top: 30px !important;padding-bottom: 30px !important;}”][/vc_column_inner][/vc_row_inner][vc_row_inner layout=”boxed”][vc_column_inner width=”3/4″ css=”.vc_custom_1624695412187{border-right-width: 1px !important;border-right-color: #dddddd !important;border-right-style: solid !important;border-radius: 1px !important;}”][vc_empty_space][megatron_heading title=”Abstract” size=”size-sm” text_align=”text-left”][vc_column_text]© 2020 Published under licence by IOP Publishing Ltd.This research aims to study one of the radiotherapy techniques of VMAT and calculate the dose distribution on phantom cylinders using the Monte Carlo EGSnrc method. VMAT is one of radiotherapy technique where is all the fractions of the dose are given continuously when the gantry rotates around the patient with manages gantry rotation speed, MLC leaf position and the dose fraction is given. The simulation process begins with head linac modeling using BEAMnrc, and using the Monte Carlo VMAT simulation uses DOSXYZnrc software. The parameters for the BEAMnrc and DOSXYZnrc simulations using information from DICOM data set rtplan AAA are read using the pycom code. The results of this study provide information about the characteristics of 6 MV photon files such as fluence, fluence energy, spectral distribution, and fluence energy distribution, and dose distribution in phantom cylinders. The VMAT Monte Carlo simulation was carried out using 300 million particles which resulted in a VMAT dose distribution in the form of a dose profile curve and an isodose curve, the result shows that the curve of VMAT simulation using phantom cylinders produced the maximum dose distribution in the isocenter.[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Author keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Delivery techniques,Dose distributions,Energy distributions,Isodose curves,Rotation speed,Simulation process,Spectral distribution,Volumetric modulated arc therapy[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Indexed keywords” size=”size-sm” text_align=”text-left”][vc_column_text]Aaa,Dicom,Egsnrc,Monte carlo,Vmat[/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”Funding details” size=”size-sm” text_align=”text-left”][vc_column_text][/vc_column_text][vc_empty_space][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][vc_empty_space][megatron_heading title=”DOI” size=”size-sm” text_align=”text-left”][vc_column_text]https://doi.org/10.1088/1742-6596/1493/1/012009[/vc_column_text][/vc_column_inner][vc_column_inner width=”1/4″][vc_column_text]Widget Plumx[/vc_column_text][/vc_column_inner][/vc_row_inner][/vc_column][/vc_row][vc_row][vc_column][vc_separator css=”.vc_custom_1624528584150{padding-top: 25px !important;padding-bottom: 25px !important;}”][/vc_column][/vc_row]